| General | |||||||
| Size | NG | 10 | 16 | 25 | 27 | 32 | 35 |
| Type of connection | Subplate mounting | ||||||
| Porting pattern | ISO 4401- 05-05-0-05 |
ISO 4401- 07-07-0-05 |
ISO 4401- 08-08-0-05 |
ISO 4401- 08-08-0-05 |
ISO 4401- 10-09-0-05 |
ISO 4401- 10-09-0-05 |
|
| Weight | kg | 9 | 11 | 18 | 19.5 | 37.5 | 75 |
| Installation position | Any | ||||||
| Ambient temperature range | °C | –20 … +50 | |||||
| Storage temperature range (with UV protection) | °C | +5 … +40 | |||||
| Maximum storage time | Years | 1 (if the storage conditions are observed, refer to the operating in- structions 07600-B) |
|||||
| Maximum relative humidity (no condensation) | % | 95 | |||||
| Protection class according to EN 60529 | IP65 (if suitable and correctly mounted mating connectors are used) |
||||||
| Maximum surface temperature | °C | 150 | |||||
| MTTFD values according to EN ISO 13849 | Years | 75 (for further details see data sheet 08012) | |||||
| Sine test according to EN 60068-2-6 | 10 … 2000 Hz / maximum 10 g / 10 cycles / 3 axes | ||||||
| Noise test according to EN 60068-2-64 | 20 ... 2000 Hz / 10 gRMS / 30 g peak / 24 h / 3 axes | ||||||
| Transport shock according to EN 60068-2-27 | 15 g / 11 ms / 3 shocks / 3 axes | ||||||
| Conformity ▶ CE according to EMC Directive 2014/30/EU, tested according to ▶ RoHS Directive |
EN 61000-6-2 and EN 61000-6-3 | ||||||
| 2011/65/EU 1) | |||||||
| Hydraulic | ||||||||||
| Size | NG | 10 | 16 | 25 | 27 | 32 | 35 | |||
| Maximum operating pressure |
▶ Ports A, B, P– Pilot control valve |
Pilot oil supply | bar | 25 … 350 | ||||||
| ▶ Port Y | bar | 350 | 350 | 350 | 270 | 350 | 350 | |||
| bar | 315 | 250 | 250 | 210 | 250 | 350 | ||||
| bar | Static < 10 (pilot control valve) | |||||||||
| bar | Static < 10 (pilot control valve) | |||||||||
| Hydraulic fluid | See table, page 8 | |||||||||
| Hydraulic fluid temperature range | °C | –20 … +80 | ||||||||
| Viscosity range ▶ Recommended ▶ Maximum admissible |
mm2/s | 30 … 45 | ||||||||
| mm2/s | 20 … 380 | |||||||||
| Maximum admissible degree of contamination of the hydraulic fluid; cleanliness class according to ISO 4406 (c) |
▶ Pilot control valve ▶ Main valve |
Class 17/15/12 3) | ||||||||
| Class 20/18/15 3) | ||||||||||
| Rated flow (Δp = 5 bar per control edge; ±10%) | 25 50 100 |
150 220 |
220 350 |
500 | 400 600 |
1000 | ||||
| Maximum flow | l/min | 170 | 460 | 870 | 1000 | 1600 | 4700 | |||
| Maximum ▶ Symbol E, E1-, R | ||||||||||
| leakage flow (inlet pressure 100 bar) |
– Main valve – Main valve + pilot control valve ▶ Symbol W6-, W8-, R3- |
l/min | 0.13 | 0.27 | 0.51 | 0.51 | 0.3 | 1.5 | ||
| l/min | 0.43 | 0.57 | 0.81 | 0.81 | 0.6 | 1.8 | ||||
| – Main valve – Main valve + pilot control valve |
l/min | 0.25 | 0.55 | 1.0 | 1.0 | 0.6 | 3.0 | |||
| l/min | 0.55 | 0.85 | 1.3 | 1.3 | 0.9 | 3.3 | ||||
| Pilot flow (at port X and Y with stepped input signal from 0 … 100%; 315 bar) |
l/min | 7 | 9 | 12 | 12 | 14 | 17 | |||
▶ Ports A, B, P